1,165 research outputs found

    Development of an ATCA IPMI controller mezzanine board to be used in the ATCA developments for the ATLAS Liquid Argon upgrade

    Get PDF
    International audienceIn the context of the LHC upgrades, a new Read-Out Driver (ROD) board for the ATLAS LAr calorimeter is being developed. xTCA (Advanced/Micro Telecom Computing Architecture) is becoming a standard in high energy physics and is a serious candidate for future readout systems. We will present our current developments to master ATCA and to integrate a large number of very high speed links (96 links/8.5 Gbps) on a ROD Evaluator ATCA board. To manage our ROD Evaluator, we have developed a versatile ATCA IPMI controller for ATCA boards which is FPGA Mezzanine Card (FMC) compliant

    Pathogenesis of HIV in the Central Nervous System

    Get PDF
    HIV can infect the brain and impair central nervous system (CNS) function. Combination antiretroviral therapy (cART) has not eradicated CNS complications. HIV-associated neurocognitive disorders (HAND) remain common despite cART, although attenuated in severity. This may result from a combination of factors including inadequate treatment of HIV reservoirs such as circulating monocytes and glia, decreased effectiveness of cART in CNS, concurrent illnesses, stimulant use, and factors associated with prescribed drugs, including antiretrovirals. This review highlights recent investigations of HIV-related CNS injury with emphasis on cART-era neuropathological mechanisms in the context of both US and international settings

    Neurocognitive function in HIV infected patients on antiretroviral therapy

    Get PDF
    OBJECTIVE To describe factors associated with neurocognitive (NC) function in HIV-positive patients on stable combination antiretroviral therapy. DESIGN We undertook a cross-sectional analysis assessing NC data obtained at baseline in patients entering the Protease-Inhibitor-Monotherapy-Versus-Ongoing-Triple therapy (PIVOT) trial. MAIN OUTCOME MEASURE NC testing comprised of 5 domains. Raw results were z-transformed using standard and demographically adjusted normative datasets (ND). Global z-scores (NPZ-5) were derived from averaging the 5 domains and percentage of subjects with test scores >1 standard deviation (SD) below population means in at least two domains (abnormal Frascati score) calculated. Patient characteristics associated with NC results were assessed using multivariable linear regression. RESULTS Of the 587 patients in PIVOT, 557 had full NC results and were included. 77% were male, 68% Caucasian and 28% of Black ethnicity. Mean (SD) baseline and nadir CD4+ lymphocyte counts were 553(217) and 177(117) cells/”L, respectively, and HIV RNA was <50 copies/mL in all. Median (IQR) NPZ-5 score was -0.5 (-1.2/-0) overall, and -0.3 (-0.7/0.1) and -1.4 (-2/-0.8) in subjects of Caucasian and Black ethnicity, respectively. Abnormal Frascati scores using the standard-ND were observed in 51%, 38%, and 81%, respectively, of subjects overall, Caucasian and Black ethnicity (p<0.001), but in 62% and 69% of Caucasian and Black subjects using demographically adjusted-ND (p = 0.20). In the multivariate analysis, only Black ethnicity was associated with poorer NPZ-5 scores (P<0.001). CONCLUSIONS In this large group of HIV-infected subjects with viral load suppression, ethnicity but not HIV-disease factors is closely associated with NC results. The prevalence of abnormal results is highly dependent on control datasets utilised. TRIAL REGISTRY ClinicalTrials.gov, NCT01230580

    Characterization of the LIGO detectors during their sixth science run

    Get PDF
    31 pages, 13 figures - See paper for full list of authorsInternational audienceIn 2009-2010, the Laser Interferometer Gravitational-wave Observatory (LIGO) operated together with international partners Virgo and GEO600 as a network to search for gravitational waves of astrophysical origin. The sensitiv- ity of these detectors was limited by a combination of noise sources inherent to the instrumental design and its environment, often localized in time or frequency, that couple into the gravitational-wave readout. Here we review the performance of the LIGO instruments during this epoch, the work done to characterize the de- tectors and their data, and the effect that transient and continuous noise artefacts have on the sensitivity of LIGO to a variety of astrophysical sources

    The variable finesse locking technique

    Get PDF
    Virgo is a power recycled Michelson interferometer, with 3 km long Fabry-Perot cavities in the arms. The locking of the interferometer has been obtained with an original lock acquisition technique. The main idea is to lock the instrument away from its working point. Lock is obtained by misaligning the power recycling mirror and detuning the Michelson from the dark fringe. In this way, a good fraction of light escapes through the antisymmetric port and the power build-up inside the recycling cavity is extremely low. The benefit is that all the degrees of freedom are controlled when they are almost decoupled, and the linewidth of the recycling cavity is large. The interferometer is then adiabatically brought on to the dark fringe. This technique is referred to as variable finesse, since the recycling cavity is considered as a variable finesse Fabry-Perot. This technique has been widely tested and allows us to reach the dark fringe in few minutes, in an essentially deterministic way

    Central nervous system antiretroviral efficacy in HIV infection: a qualitative and quantitative review and implications for future research

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>There is conflicting information as to whether antiretroviral drugs with better central nervous system (CNS) penetration (neuroHAART) assist in improving neurocognitive function and suppressing cerebrospinal fluid (CSF) HIV RNA. The current review aims to better synthesise existing literature by using an innovative two-phase review approach (qualitative and quantitative) to overcome methodological differences between studies.</p> <p>Methods</p> <p>Sixteen studies, all observational, were identified using a standard citation search. They fulfilled the following inclusion criteria: conducted in the HAART era; sample size > 10; treatment effect involved more than one antiretroviral and none had a retrospective design. The qualitative phase of review of these studies consisted of (i) a blind assessment rating studies on features such as sample size, statistical methods and definitions of neuroHAART, and (ii) a non-blind assessment of the sensitivity of the neuropsychological methods to HIV-associated neurocognitive disorder (HAND). During quantitative evaluation we assessed the statistical power of studies, which achieved a high rating in the qualitative analysis. The objective of the power analysis was to determine the studies ability to assess their proposed research aims.</p> <p>Results</p> <p>After studies with at least three limitations were excluded in the qualitative phase, six studies remained. All six found a positive effect of neuroHAART on neurocognitive function or CSF HIV suppression. Of these six studies, only two had statistical power of at least 80%.</p> <p>Conclusions</p> <p>Studies assessed as using more rigorous methods found that neuroHAART was effective in improving neurocognitive function and decreasing CSF viral load, but only two of those studies were adequately statistically powered. Because all of these studies were observational, they represent a less compelling evidence base than randomised control trials for assessing treatment effect. Therefore, large randomised trials are needed to determine the robustness of any neuroHAART effect. However, such trials must be longitudinal, include the full spectrum of HAND, ideally carefully control for co-morbidities, and be based on optimal neuropsychology methods.</p

    Calibration and sensitivity of the Virgo detector during its second science run

    Full text link
    The Virgo detector is a kilometer-length interferometer for gravitational wave detection located near Pisa (Italy). During its second science run (VSR2) in 2009, six months of data were accumulated with a sensitivity close to its design. In this paper, the methods used to determine the parameters for sensitivity estimation and gravitational wave reconstruction are described. The main quantities to be calibrated are the frequency response of the mirror actuation and the sensing of the output power. Focus is also put on their absolute timing. The monitoring of the calibration data as well as the parameter estimation with independent techniques are discussed to provide an estimation of the calibration uncertainties. Finally, the estimation of the Virgo sensitivity in the frequency-domain is described and typical sensitivities measured during VSR2 are shown.Comment: 30 pages, 23 figures, 1 table. Published in Classical and Quantum Gravity (CQG), Corrigendum include
    • 

    corecore